Photos

  • Album cover: Work

    Work

  • Album cover: Engineer

    Engineer

Preview of gMNsq2q9rbL6Gpa1ddPa.
Preview of 5PumJz7ikMacSQbUch9Q.
Preview of 37gXHfaRC8rr8Z1bRJ3r.
Preview of zEOsZIFlYtVCJAXucVqO.
Preview of 80aH1zL2OcFhI4o5Rg26.
Preview of RSgt3AyvoyDyydKDaxLy.
Preview of 59cyYrSOZlJdLNTSQPX1.
Preview of FfFJAPgQ2vwcD8kW3iku.
Preview of CeUu8UdZLbIZIsDcYzf6.
Preview of New Baxi 825.
Preview of EI0f0FcdFDSQWYj0w7TM.
Preview of pmsSgwlc2wPCqjBloGLG.
Preview of New Worcester 30i.
Preview of AjpYnz0gcmkdRKwhL3Yx.
Preview of jtrgc8btWu7TWRQtiuyc.
Preview of tsPV1W5mr5F4ihi1DB15.
Preview of 9jK3cY3kveDWuwbeGJa9.
Preview of 71T5bJDUZCRnAIqy4iUU.
Preview of jlYdPh2IIM1TTN36lFLc.
Preview of Capped off gas meter and installed bottles..
Preview of Range cooker install.
Preview of New livery on the van.
Preview of Focalpoint Blenheim HE install.
Preview of Baxi 836 install.
Preview of New 28mm gas run to boiler.
Preview of Electric fire with surround install.
Preview of New changeover valve and pipework for a brand new caravan.
Found plate heat exchanger blocked so i removed it, flushed it with industrial cleaner and refitted. Hot water now works a treat
Both boilers have been patched up so much over the years that they won't adjust any more and parts from Italy were getting harder to find so we replaced both the entire burners while we can still get them
The boiler hadn't been serviced in years and this is what i found inside the filter. Cleaned it out and customer is now set up on a regular service schedule
During a drain down to replace a boiler part i found the water was brown, indicating the radiators were going rusty inside. System booked in for a flush and the inhibitor added to stop it happening again
New gas fire installation
Supply pipe to outside tap burst in the cold weather. Section cut out and replaced. Isolation valve added inside the property and pipe lagged outside
Customer wanted a new gas fire installed. Old fire taken out and new one put in its place
Preview of Commercial boiler service.
This is a Worcester 15SBi and the previous engineer had refused to repair it saying it must be replaced. I ordered the new manifold and replaced it. Cleaning everything disturbed and replacing seals as i went. Needs upgrading but now it's bought the customer some time to save
Radiators very slow to warm, boiler kettling. The magnetite build up on this one was so bad there was only a tiny hole left for the water to get through. Pump and valves replaced and system flushed and inhibited